Meriam > Meriam M402 Pressure Calibrator Dual Sensors. P1 = ± 15 PSIG. P2 = -15 to + 500 PSIG
Meriam M402 Pressure Calibrator Dual Sensors. P1 = ± 15 PSIG. P2 = -15 to + 500 PSIG
Product Description
Meriam’s M4 Series Handheld Precision Calibrator / Data Logger boasts an impressive array of features, functions and a terrific accuracy specification! The M400 includes one pressure sensor and one mA/V instrument. Chose from differential, gauge, compound or absolute pressure types and ranges from 10" H2O to 3000 PSIG full scale. Need two ranges for wider utility? No problem!
The M402 can be configured with any two compound or absolute type sensors. Accuracy is ±0.025% of Full Scale. Accuracy is maintained over operating temperatures from -20º to +50º C (-4º to +122º F). Data Logging is standard on all models.
All M4 Series handhelds provide convenient electrical signal measurement and sourcing. Measure ±50V or ±100mA, source 24VDC and measure mA, sink V or mA, or source precise VDC or mA DC values using the supplied test leads. Accuracy is ±(0.015% of Reading + 0.002 units) over the entire operating temperature range. Source or sink values are easily entered using the Adaptive Interface Reel.
Temperature: Operating: -4 to 122°F (-20 to 50°C) Storage: -40 to 140°F (-40 to 60°C)
Connections: Pressure: 1∕8" NPT (female) Electrical: Standard banana jacks on ¾" centers Firmware updates, data retrieval: USB mini-B (female)
Power: Portable service: Four (4) AA alkaline batteries provides 30+ hours of continuous measurement service Operation with PC: Power over USB using USB type A to mini-B cable (requires high power 500 mA port)
Display: 128 x 128 pixel (2" x 2" viewable) monochrome display with backlight
Keypad: Sealed membrane keypad with molded dome switches and integrated Adaptive Interface Wheel
Enclosure: 8.5" L x 3.75" W (max.) x 2.25" D (max.), polycarbonate case, Softflex® over-molded bumpers, IP40
Firmware Features: Sensor Zero, Sensor Damping, Averaging (pending), Minimum/Maximum capture, Tare (pending), Units Select, Data Logging, Data Logging Record Indicator, Selectable Off Timer, Selectable Backlight Timer, Adjustable Contrast, Adjustable Backlight Brightness, Battery Monitor
Data Logging: Standard on all M4 models. Select Data Logging from the Setup key menu and then enter the desired Interval and Duration parameters using the keypad controls. For M400 single pressure sensor units, pressure, VDC and mA DC values are saved to the SD card at each interval. M402 dual pressure sensor units log both pressure values plus VDC and mA DC values.
The supplied SD card is located under the battery compartment cover. Data can be moved to a host PC using the supplied USB cable and PC utility or by inserting the SD card in a compatible PC to copy the desired files. The M4 handhelds and SD card supports 100 data files.
DC voltage and Current Measurement: Connections to transmitters or transducers under test are made using the 1/8" banana jacks located in the lower end of the handheld. Alternatively, these jacks can provide temporary 24V DC power and measure loop current simultaneously. Sourcing DC volts and current is also a standard feature. Use the Sensor key to highlight the sensor desired and then use the Setup key to select the desired function. The Adaptive Interface Wheel is used to set precise values or configure step or ramp sourcing programs (step and ramp are pending) to test receiving devices.
Process Measurement Company offers INSTRUMENT RENTAL, INSTRUMENT REPAIR & CALIBRATION (on site or in our lab).
Process Measurement Company is ISO 9001:2008 Certified.